Items
|
Descriptions
|
|
Input
|
Power input
|
Recommend Voc range: 220V: 360~450Vdc; 380V: 550~900Vdc
Recommend Vmp range: 220V: 250~350Vdc. 380V: 450~900Vdc
Max DC input: 450Vdc(220v class), 380V 900Vdc(380v class)
|
|
AC 1PH, 220V(-15%) ~ 240V(+10%)
AC 3PH, 380V(-15%) ~ 440V(+10%)
|
|
Allowable range
|
Voltage fluctuating range: -15%~10%; voltage unbalance <3%;
frequency: 47Hz~63Hz
|
|
Output
|
Output voltage
|
220V class: 1PH or 3PH 220V
380V class: 3phase 380V
0V~input voltage, tolerance<5%
|
|
Output frequency range
|
0.1 -500.0Hz
|
|
Performance
|
Overload capacity
|
G mode (heavy duty): 150% of rated current: 60s, 170% of rated current: 12s, 190% of rated current: 1.5s
P mode (light duty): 120% of rated current: 60s, 150% of rated current: 3s
|
|
Frequency resolution
|
Digital setting: 0.01Hz
Analog setting: Max. frequency*0.025%
|
|
Carrier frequency
|
0.8 ~ 8 kHz, can be automatically adjusted according to load characteristics
|
|
Input/output
|
Analog input AI
|
1 channels AI: 0/4~20mA, 0-10V
|
|
Analog output AO
|
1 channels AO: 0/4~20mA, 0-10V
|
|
Digital input
|
5 digital inputs, NPN / PNP, 1ph 0.75 and 1.5kW with 4DI.
|
|
Digital output
|
1 digital output, 1 relay output
|
|
PFI / PFO
|
1 channel pulse frequency input and output
|
|
Communication
|
Built-in RS485 interface with Modbus RTU
|
|
Control
functions
|
Motor control mode
|
VF control, Sensor-less vector control
|
|
Run command channel
|
Operation panel setting, control terminal setting, communication setting
|
|
Frequency setting channel
|
Operation panel, communication, UP/DOWN regulated value, AI, PID, multi-step speed, PFI
|
|
DC braking
|
Braking time: 0.0s~60.0s, braking current: 0.0%~100.0% of rated current
|
|
Jog
|
Jogging frequency range: 0.00Hz~Maximum frequency
|
|
AVR
|
Automatic voltage regulation
|
|
Automatic carrier frequency
|
Automatically regulate carrier frequency according to load characteristic
|
|
Environment
|
Protection
|
Over-current, over-voltage, under-voltage, phase loss, output interphase short circuit, overheat,
motor overload, external failure, lost connection of analog input, stall prevention, etc.
|
|
Altitude
|
With altitude below 1000m, derate >1000m
|
|
Operating
|
-10~+50℃ / 20~90%RH, without condensation water drop
|
|
Storage temperature
|
-20~+60℃
|
|
Vibration
|
<5.9m/s2 (0.6g)
|
|
Structure
|
Degree of protection
|
IP20
|
|
Cooling mode
|
Force-air cooling
|