Items |
Descriptions |
| Input |
Rated voltage, frequency |
3-phase: 380V, 50Hz/60Hz
3-phase: 660V, 50Hz/60Hz |
| Allowable range |
Voltage fluctuating range: -15%~10%; voltage unbalance: <3%; frequency: 47Hz~63Hz |
| Output |
Output voltage |
Three-phase, 0V~input voltage, deviation<5% |
| Output frequency range |
VF: 0.00 - 400.00Hz
Vector: 0.00 - 200.00Hz |
| Performance |
Overload capacity |
150% of rated current for 60s, 180% of rated current 15s, 200% of rated current 2s
|
| Frequency resolution |
Digital setting: 0.01Hz; simulation setting:<2% of the maximum frequency |
| Output frequency accuracy |
Analog setting: <±2% of the maximum frequency; digital setting: 0.01Hz |
| Input/output |
Analog input AI |
2 channels AI: 0/4~20mA, 0-10V |
| Analog output AO |
2 channels AO: 0/4~20mA, 0-10V |
| Digital input |
5 digital inputs, NPN / PNP |
| Digital output |
2 digital output, 2 relay output |
| PFI / PFO |
1 channel pulse frequency input and output |
| Communication |
Built-in RS485 interface with Modbus RTU, optional ModbusTCP, Profibus, Profinet |
Control
functions |
Motor control mode |
VF, VF+PG, SVC, VC+PG |
| Run command channel |
Operation panel setting, control terminal setting, communication setting |
| Frequency setting channel |
Operation panel, communication, UP/DOWN regulated value, AI, PID, multi-step speed, PFI, logic |
| DC braking |
Braking time: 0.0s~60.0s, braking current: 0.0%~100.0% of rated current |
| Acceleration & deceleration |
Linear, S curve ACC/DEC |
| Jog |
Jogging frequency range: 0.10Hz~50.00Hz |
| AVR |
Automatic voltage regulation |
| Automatic carrier frequency |
Automatically regulate carrier frequency according to load characteristic and environment temperature |
| Droop control |
Suitable for multi-motor drive control |
| Multistep speed method |
48 steps |
| Multi-modes PLC |
8 sets PLC modes, max. 48 steps |
| Position control |
Zero-speed position lock, position control |
| Logic unit |
Comparator, logic unit, trigger, arithmetic unit, |
| Others |
Tracking start, stall prevention, oscillation suppression, accurate dead zone compensation functions |
| Environment |
Protection |
Over-current, over-voltage, under-voltage, phase loss, output interphase short circuit, overheat,
motor overload, external failure, lost connection of analog input, stall prevention, etc. |
| Altitude |
With altitude below 1000m, derate >1000m |
| Operating |
-10~+40℃ / 20~90%RH, without condensation water drop |
| Storage temperature |
-20~+60℃ |
| Vibration |
<5.9m/s2 (0.6g) |
| Structure |
Degree of protection |
IP30 |
| Cooling mode |
Force-air cooling |